Some devices have no ports after ONOS cluster restart

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Closed (View Workflow)
    • Priority: Critical
    • Resolution: Done
    • Affects Version/s: 1.2.0
    • Fix Version/s: 1.2.0
    • Component/s: None
    • Labels:
      None
    • Environment:

      commit 2dd48e6f86ab7760f8fa5a2241fbd28c7d35d49d
      OVS 2.3 with OpenFlow 1.3

    • Epic Link:
    • Sprint:
      Cardinal Sprint 5 (5/18-5/22), Cardinal Sprint 6 (5/26-5/29)

      Description

      When restarting a 7 node ONOS cluster with a topology connected I have observed some switches have no ports in ONOS once they reconnect. I have been able to reproduce this several times in the last few days.

      When looking at the packet capture of the test, it looks like the switches do reply to the port description request with the correct ports.

        Attachments

        1. logs.zip
          434 kB
        2. ports.pcap
          254 kB