Uploaded image for project: 'ONOS'
  1. ONOS
  2. ONOS-2511

Error on OFchannel handler when connecting to 1.3 OVS

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Closed (View Workflow)
    • Priority: Major
    • Resolution: Done
    • Affects Version/s: None
    • Fix Version/s: 1.3.0
    • Component/s: None
    • Labels:
    • Environment:

      Description

      1) start mininet with 1.3 OVS:
      sudo mn --topo linear,2 --switch ovsk,protocols=OpenFlow13 --controller remote,ip=192.168.57.101

      2) single cell ONOS, log:

      2015-07-31 15:10:26,543 | ERROR | ew I/O worker #1 | OFChannelHandler | 166 - org.onosproject.onos-of-ctl - 1.3.0.SNAPSHOT | OFBadRequestErrorMsgVer13(xid=3, code=BAD_TYPE, data=OFGroupStatsRequestVer13(xid=3, flags=[], group=all)) from switch org.onosproject.driver.handshaker.NiciraSwitchHandshaker [/192.168.57.110:40960 DPID[00:00:00:00:00:00:00:02]] in state ACTIVE
      2015-07-31 15:10:26,543 | ERROR | ew I/O worker #2 | OFChannelHandler | 166 - org.onosproject.onos-of-ctl - 1.3.0.SNAPSHOT | OFBadRequestErrorMsgVer13(xid=1, code=BAD_TYPE, data=OFGroupStatsRequestVer13(xid=1, flags=[], group=all)) from switch org.onosproject.driver.handshaker.NiciraSwitchHandshaker [/192.168.57.110:40961 DPID[00:00:00:00:00:00:00:01]] in state ACTIVE
      2015-07-31 15:10:26,545 | ERROR | ew I/O worker #1 | OFChannelHandler | 166 - org.onosproject.onos-of-ctl - 1.3.0.SNAPSHOT | OFBadRequestErrorMsgVer13(xid=4, code=BAD_TYPE, data=OFGroupDescStatsRequestVer13(xid=4, flags=[])) from switch org.onosproject.driver.handshaker.NiciraSwitchHandshaker [/192.168.57.110:40960 DPID[00:00:00:00:00:00:00:02]] in state ACTIVE
      2015-07-31 15:10:26,547 | ERROR | ew I/O worker #2 | OFChannelHandler | 166 - org.onosproject.onos-of-ctl - 1.3.0.SNAPSHOT | OFBadRequestErrorMsgVer13(xid=2, code=BAD_TYPE, data=OFGroupDescStatsRequestVer13(xid=2, flags=[])) from switch org.onosproject.driver.handshaker.NiciraSwitchHandshaker [/192.168.57.110:40961 DPID[00:00:00:00:00:00:00:01]] in state ACTIVE
      2015-07-31 15:10:36,627 | ERROR | ew I/O worker #1 | OFChannelHandler

        Attachments

        No reviews matched the request. Check your Options in the drop-down menu of this sections header.

          Activity

            People

            Assignee:
            Unassigned
            Reporter:
            suibin suibin
            Votes:
            0 Vote for this issue
            Watchers:
            1 Start watching this issue

              Dates

              Created:
              Updated:
              Resolved: