      Description

      SP2MP intents sometimes do not install flows correctly when applying VLAN treatments to packets.

      VLAN treatment will be applied to packets at ingress into the network, but subsequent flows in the intent will attempt to match on the old VLAN ID instead of the new VLAN ID set by the VLAN treatment