Uploaded image for project: 'ONOS'
  1. ONOS
  2. ONOS-5214

Issue With Meters REST API- DROP Type causing NPE,Wrong UNIT Type & Meter Type not throwing Exception on Response Body to prevent to create meter with Wrong Band Type Or Wrong Unit type

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Closed (View Workflow)
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: 1.7.0, 1.6.1, 1.8.0
    • Fix Version/s: 1.7.0, 1.6.1, 1.8.0
    • Component/s: None
    • Labels:
      None
    • Environment:

      onos -1.6

    • Story Points:
      2

      Description

      1. Create a meter by Using meters REST API - POST /meters/

      {deviceId}

      2. Create Meter Of Wrong Type or a BAND of wrong type leads to NPE

      { "code": 500, "message": "com.google.common.base.Preconditions.checkNotNull(Preconditions.java:212)" }

      3. Create Meter Of Wrong UNIT Type leads to craeting meter of wrong Unit type.

      Expected Result:

      1. In case of Wrong Band Type, it should throw exception like "he requested type is not defined for meter".
      2. In case of "DROP" Band Type, it should create a meter without precedence.
      3. In case of Wrong Unit Type, It should throw exception like "he requested unit is not defined for meter"